3.2.1.1. Alarms
The following alarms are supported by the handset:
- Manual Alarm
- Non Movement Alarm
- Man Down Alarm
- Time Alarm
- Escape Alarm
General values are entered for all alarms. Furthermore, parameters are preconfigured for each alarm type, which can be adapted individually however for the corresponding application.
General Settings
These values are used in general for all alarm types within an operating mode.
Procedure:
- Select the Additional Features icon in the main menu.
- Select Configuration.
- Enter the five-position service PIN and confirm with OK.
- Select one of the three operating modes.
- Select Alarms.
- Select General Settings.
- Change the values of the following parameters:
Parameters | Basic mode | Alarm mode | PNG mode |
|---|---|---|---|
Alarm number(s) / Alarm Destination | Alarm Destination 1 <empty> | - | - |
Alarm Destination 2 <empty> | - | - | |
Alarm Destination 3 <empty> | - | - | |
Call retry counter | 15 | - | - |
Calling Time | 30 sec | - | - |
Audio Channel | Hands-free | - | - |
Manual alarm
You can configure all settings here for the manual alarm, in other words for the alarm triggered with the red alarm key.
Depending on how the red alarm key is pressed (SP: Short press, LP: Long press), different alarms are signaled (Alarm/PNG) and different alarm destinations are dialed (Basic).
Procedure:
- Select the Additional Features icon in the main menu.
- Select Alarm Configuration.
- Enter the five-position service PIN and confirm with OK.
- Select one of the three operating modes.
- Select Alarms.
- Select Manual Alarm.
- Change the values of the following parameters:
Parameters | Basic mode | Alarm mode | PNG mode |
|---|---|---|---|
Short press Alarm Key | On | On | On |
Long press Alarm Key | On | On | On |
Keypad Locked | Key active | Key active | Key active |
SP Pre-Alarm Time | 0 sec. <0-300 sec> | 0 sec. <0-300 sec> | 0 sec. <10-90 sec> |
SP Pre-Alarm Ringtone | 31 Alarm 5 | 31 Alarm 5 | 31 Alarm 5 |
SP Pre-Alarm Volume | 50 | 50 | 50 |
SP Alarm Signal | On | On | On |
SP Alarm Signal Ringtone | 31 Alarm 5 | 31 Alarm 5 | 31 Alarm 5 |
SP Alarm Signal Volume | 100 | 100 | 100 |
LP Pre-Alarm Time | 0 sec. <0-300 sec> | 0 sec. <0-300 sec> | 0 sec. <10-90 sec> |
LP Pre-Alarm Ringtone | 32 Alarm 6 | 32 Alarm 6 | 32 Alarm 6 |
LP Pre-Alarm Volume | 50 | 50 | 50 |
LP Alarm Signal | On | On | On |
LP Alarm Signal Ringtone | 32 Alarm 6 | 32 Alarm 6 | 32 Alarm 6 |
LP Alarm Signal Volume | 100 | 100 | 100 |
No-Motion Alarm
The No-Motion Alarm can be activated optionally. It is triggered if the sensors identify lack of movement over a defined configurable period of time.
Procedure:
- Select the Additional Features icon in the main menu.
- Select Configuration.
- Enter the five-position service PIN and confirm with OK.
- Select one of the three operating modes.
- Select Alarms.
- Select No-Motion Alarm.
- Change the values of the following parameters:
Parameters | Basic mode | Alarm mode | PNG mode |
|---|---|---|---|
Activation | On | On | On |
Response Time | 90 sec. <10-900 sec> | 90 sec. <10-900 sec> | 90 sec. <10-90 sec> |
Pre-alarm Time | 15 sec. <0-300 sec> | 15 sec. <0-300 sec> | 15 sec. <0-30 sec> |
Sensitivity level | High | High | High |
Man Down Alarm
The Man Down Alarm can be activated optionally. It is triggered if the sensors identify undue tilting of the handset over a defined configurable period of time (i.e. deviation from the vertical position).
Procedure:
- Select the Additional Features icon in the main menu.
- Select Configuration.
- Enter the five-position service PIN and confirm with OK.
- Select one of the three operating modes.
- Select Alarms.
- Select Man Down Alarm.
- Change the values of the following parameters:
Parameters | Basic mode | Alarm mode | PNG mode |
|---|---|---|---|
Activation | On | On | On |
Response Time | 90 sec. <10-900 sec> | 90 sec. <10-900 sec> | 90 sec. <10-90 sec> |
Pre-alarm Time | 15 sec. <0-300 sec> | 15 sec. <0-300 sec> | 15 sec. <0-30 sec> |
Sensitivity level | High | High | High |
Time Alarm
The Time Alarm can be activated optionally. It is triggered if a timed alarm is not acknowledged in time by the user.
Procedure:
- Select the Additional Features icon in the main menu.
- Select Configuration.
- Enter the five-position service PIN and confirm with OK.
- Select one of the three operating modes.
- Select Alarms.
- Select Time Alarm.
- Change the values of the following parameters:
Parameters | Basic mode | Alarm mode | PNG mode |
|---|---|---|---|
Activation | Off | Off | Off |
Response Time | 15 min. <1-120 min.> | 15 min. <1-120 min.> | 15 min. <1-15 min.> |
Pre-alarm Time | 15 sec. <0-300 sec> | 15 sec. <0-300 sec> | 15 sec. <0-15 sec> |
Escape Alarm
The Escape Alarm can be activated optionally. It is triggered if the sensors identify undue violent movement of the handset over a defined configurable period of time.
Procedure:
- Select the Additional Features icon in the main menu.
- Select Configuration.
- Enter the five-position service PIN and confirm with OK.
- Select one of the three operating modes.
- Select Alarms.
- Select Escape Alarm.
- Change the values of the following parameters:
Parameters | Basic mode | Alarm mode | PNG mode |
|---|---|---|---|
Activation | Off | Off | Off |
Response Time | 30 sec. <10-900 sec> | 30 sec. <10-900 sec> | 30 sec. <10-90 sec> |
Pre-alarm Time | 15 sec. <0-300 sec> | 15 sec. <0-300 sec> | 15 sec. <0-30 sec> |
Sensitivity level | High | High | High |
Alarm Signal
You can define the acoustic signaling of pre-alarms and alarms here. The following signals start quietly and reach their configured maximum value after a short time.
Procedure:
- Select the Additional Features icon in the main menu.
- Select Configuration.
- Enter the five-position service PIN and confirm with OK.
- Select one of the three operating modes.
- Select Alarms.
- Select Alarm Signal.
- Select Pre-Alarm or Alarm Signal.
- Change the values of the following parameters:
Parameters | Basic mode | Alarm mode | PNG mode |
|---|---|---|---|
Pre-Alarm | |||
| On | On | On |
| 31 Alarm 5 | 31 Alarm 5 | 31 Alarm 55 |
| 50 | 50 | 50 |
| Off | Off | Off |
Alarm Signal | |||
| On | On | On |
| 27 Alarm 1 | 27 Alarm 1 | 27 Alarm 1 |
| 100 | 100 | 100 |
| Off | Off | Off |