Direct link to Firmware file
Introduction
Here you can find information on how you can upgrade a device via auto provisioning, just by inserting URL directly to the Firmware file without using the Gigaset File structure.
N510 IP PRO
Via auto provisioning you can configure use the S_SPECIAL_DATA_SRV parameter to define the URL to the firmware file. The name of the file is important as the naming is used to define if a new software is available for download.
Dependent on the software version, one of the parameters below can be used.
Parameter Name | Possible Values | WebUI availability | Description |
|---|---|---|---|
BS_IP_Data1.aucS_USER_FIRMWARE_URL | string max.74 chars [0-9,a-z,A-Z,.,-] | Yes | Firmware update using S_SPECIAL_DATA_SRV will be performed in the following situations: Example: <BS_IP_Data1.aucS_USER_FIRMWARE_URL class="string" value='"http://profile.gigaset.net/device/42/merkur245_42.bin"'/> Important is to use the naming like described in the example: "merkur"softwareversion"_42.bin" |
S_SPECIAL_DATA_SRV | string max.74 chars [0-9,a-z,A-Z,.,-] | Yes | Firmware update using S_SPECIAL_DATA_SRV will be performed in the following situations: Example: <S_SPECIAL_DATA_SRV class="string" value='"http://profile.gigaset.net/device/42/merkur245_42.bin"'/> Important is to use the naming like described in the example: "merkur"softwareversion"_42.bin" |
The same parameter can also be set using the following parameter name | |||
BS_IP_Data1.aucS_SPECIAL_DATA_SRV | string max.74 chars [0-9,a-z,A-Z,.,-] | Yes | Firmware update using BS_IP_Data1.aucS_SPECIAL_DATA_SRV will be performed in the following situations: Example: <SYMB_ITEM ID="BS_IP_Data1.aucS_SPECIAL_DATA_SRV[0]" class="symb_item" value='"http://profile.gigaset.net/device/42/merkur245_42.bin"'/> Important is to use the naming like described in the example: "merkur"softwareversion"_42.bin" |
When does the device download the new firmware
Procedure | Upgrade |
|---|---|
Factory reset | No upgrade |
After time (once a day) | Upgrade will be started |
Reboot | Upgrade will be started |
Via web-interface "Update profile" | No upgrade |
N720 IP PRO
Via provisioning you can send the URL where the firmware files are located for the DECT manager and DECT base stations.
To start the download, you need to start the provisioning process, this can be done via:
- Restart of the device.
- After time, default once a day the device will start the provisioning process.
- Check-sync - NOTIFY request send by SIP platform
- Web-interface, start provisioning
We advise to upgrade when you are on location so you can monitor the upgrade process as up to 30 basestations can be upgraded and up to 100 handsets are used.
Parameter Name | WebUI availability | Description |
|---|---|---|
S_SPECIAL_DATA_SRV_IWU | No | Direct link towards DECT Manager firmware file. Example: <S_SPECIAL_DATA_SRV_IWU class="string" value='"http://192.168.178.101/device/firmware/server_einstein_iwu095.bin"'/> Name of file should be "server_einstein_iwu_Softwareversion.bin" Restart/Sync/After time is needed to start upgrade. |
S_SPECIAL_DATA_SRV_SAT | No | Direct link towards DECT Basestation firmware file. Example: <S_SPECIAL_DATA_SRV_SAT class="string" value='"http://192.168.178.101/device/firmware/sat7109500000000.bin"'/> Naming of file should be like in the above example. Restart/Sync/After time is needed to start upgrade. |
Maxwell Basic, 2 and 3